Categories
* images are for illustrative purposes only

FLUKE DIGITAL MULTIMETER 115

  • bvseo_sdk, net_sdk, 2.2.0.2
  • getAggregateRating, method:CLOUD, 546ms
  • REVIEWS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 500ms;
FLUKE INSTRUMENTS 115
UOM: PC
Price w/GST:
$262.15


Large white LED backlight to work in poorly lit areas
Resistance and continuity
Frequency and capacitance
Maximum Voltage ac/dc 600V
10A ac/dc current measurement (20 A overload for 30-seconds max)
Min/Max/Average to record signal fluctuations
CAT III 600 V safety rated
DC millivolts Range:  600.0 mV
  Resolution:  0.1 mV
  Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution:  6.000 V / 0.001 V
  Range/Resolution:  60.00 V / 0.01 V
  Range/Resolution:  600.00 V / 0.1 V
  Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms Range:  600.0 mV
  Resolution:  0.1 mV
  Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution:  6.000 V / 0.001 V
  Range/Resolution:  60.00 V / 0.01 V
  Range/Resolution:  600.0 V / 0.1 V
  Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range:  600 ?
  Resolution:  1 ?
  Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms Range/Resolution: 600.0 Ω / 0.1 Ω
  Range/Resolution: 6.000 kΩ / 0.001 kΩ
  Range/Resolution: 60.00 kΩ / 0.01 kΩ
  Range/Resolution: 600.0 kΩ / 0.1 kΩ
  Range/Resolution: 6.000 MΩ / 0.001 MΩ
  Accuracy:  0.9 % + 1
  Range/Resolution: 40.00 MΩ / 0.01 MΩ
  Accuracy:  5 % + 2
Diode Test Range/Resolution:  2.00 V / 0.001 V
  Accuracy:  0.9% + 2
Capacitance Range/Resolution:  1000 nF / 1 nF
  Range/Resolution:  10.00 µF / 0.01 µF
  Range/Resolution:  100.0 µF / 0.1 µF
  Range/Resolution:  9999 µF / 1 µF
  Range/Resolution:  100 µF to 1000 µF
  Accuracy:  1.9% + 2
  Range/Resolution:  > 1000 µF
  Accuracy:  5% + 20%
Lo-Z Capacitance Range:  1 nF to 500 µF
  Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500Hz) Range/Resolution:  6.000 A / 0.001 A
  Range/Resolution:  10.00 A / 0.01 A
  Accuracy:  1.5% + 3
     20 A overload for 30-seconds max
DC amps Range/Resolution:  6.000 A / 0.001 A
  Range/Resolution:  10.00 A / 0.01 A
  Accuracy:  1.0% + 3
     20 A overload for 30-seconds max
Hz (V or A input)2 Range/Resolution:  99.99 Hz / 0.01 Hz
  Range/Resolution:  999.9 Hz / 0.01 Hz
  Range/Resolution:  9.999 kHz / 0.001 kHz
  Range/Resolution:  50 kHz / 0.01 kHz
  Accuracy:  0.1% + 2