Categories
* images are for illustrative purposes only

FLUKE DIGITAL MULTIMETER 116

  • bvseo_sdk, net_sdk, 2.2.0.2
  • getAggregateRating, method:CLOUD, 546ms
  • REVIEWS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 500ms;
FLUKE INSTRUMENTS 116
UOM: PC
Price w/GST:
$337.05


Built-in thermometer for HVAC applications
Microamps to test flame sensors
Low input impedance: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak™)
CAT III 600 V safety rated
DC millivolts Range/resolution 600.0 mV / 0.1 mV
  Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
  Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
  Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
  Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
  Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
  Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
    500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
  Accuracy 0.9% + 1
  Range/Resolution 40.00 MΩ / 0.01 MΩ
  Accuracy 5% + 2
Diode Test Range/resolution 2.00 V / 0.001 V
  Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
  Accuracy 1.9% + 2
  Range/resolution > 1000 μF
  Accuracy 5% + 20%
Lo-Z Capacitance Range 1 nF to 500 μF
  Accuracy 10% + 2 typical
Temperature² Range/resolution -40°C to 400°C / 0.1°C
(Type-K thermocouple) Accuracy 1% + 10²
  Range/resolution -40°F to 752°F / 0.2°F
  Accuracy 1% + 18²
AC μA true-rms (45 Hz to 500 Hz) Range/resolution 600.0 μA / 0.1 μA
  Accuracy 1.5% + 3
DC μamps Range/resolution 600.0 μA / 0.1 μA
  Accuracy 1.0% + 2
Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
    999.99 Hz / 0.1 Hz
    9.999 Hz / 0.001 Hz
    50.00 Hz / 0.01 Hz
  Accuracy 0.1% + 2
  • bvseo_sdk, net_sdk, 2.2.0.2
  • getReviews, method:CLOUD, 32ms
  • REVIEWS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 500ms;Thread was being aborted.